Iso99
Iso99 is a simple post-processing tool suitable for THETA-results. THETA results can be analysed in a simple manner without any format conversions.
Availability
First it needs to be checked whether iso99 is already available in the THETA version. Therefore, check taudir/src/addons for isoplot99. If iso is not there, Björn Witha (bjoern.witha@forwind.de) can provide the necessary .tar file iso99.tar.
Usage on FLOW
In case iso99 was not initially in the taudir-directory, untar it
tar -xf iso99.tar
make the following patch (note that this patch might be also necessary in case iso99 was initially in the taudir)
sed -i "s/fl_drw_box/fl_draw_box/g" isoplot99/canvas.c
add it to the addons and compile it via
mv isoplot99/ taudir/src/addons/ cd taudir/ make iso99
Now, there exists an executable called iso99 under taudir/bin/ ready for the post-processing of THETA results. Keeping to the Sloshing_Tank example as taken to introduce THETA, invoke iso99 with
[<Username>@flow Sloshing_Tank-S-L2]$ ~/taudir/bin/iso99 ~/Theta_Test/Grids_1/tank.grid PATH.pval.374 PATH.pval.748
Afterwards, the IsoPlot99 window opens. Select variables like pressure or velocity by clicking on (none) and make the solution colorful by clicking the circles on the left next to the bar.
Both solutions are shown on the grid. Of course it is possible to only show one solution.
Via Plot/Cut plane or Plot/Boundary mask a different cross section can be selected or the boundary mapping can be checked. It can be checked whether the Markers are correctly set in the parameter file.